Skip to main content

Taylor’s Approach to Neuraxial Anesthesia Model

Download STL Files

This model is intended to support teaching and facilitate understanding of Taylor’s approach in patients with challenging spinal anatomy.

To design the model, L5 vertebra (www.thingiverse.com/thing:4801717) and the sacrum (www.thingiverse.com/thing:4946668) were downloaded. The final STL file was then created using Tinkercad.com by removing unnecessary pelvic components while preserving the anatomical relationship between the posterior superior iliac spine and the L5–S1 interspace.

A base was added with a QR code linking to a Dropbox document adapted from NYSORA that describes Taylor’s approach. And an expired epidural needle was then heated and inserted into the plastic to visually demonstrate the needle trajectory: an insertion point 1 cm inferior and 1 cm medial to the posterior superior iliac spine, directed 45 degrees cephalad and 45 degrees medially to access the spinal canal through the L5–S1 interlaminar space.


Print difficulty: Moderate

Material: PLA (2 colors)

Nozzle: 0.4

Layer height: 0.2

Supports: Organic supports, touching build plate only for the Spine, and no support for the base

Post-processing time: Approximately 15 minutes

Total filament required: Less than 300 g

The base should be printed separately using a 0.4 mm nozzle and a 0.2 mm layer height. For optimal QR code quality, begin with a dark filament, then pause the print and switch to white filament at 2.4 mm.

Taylor Approach (Video)